The light meter is designed to meet the measurement requirements of safety engineers, health, industrial, safety offices and light quality control in various environments like factory, school, construction, etc. Features : Large backlight LCD display with 40-segment bar graph Peak Read more…


Features : Humidity and temperature measuring Dew point temperature Calibration function User selectable units Data hold Large backlight LCD display Specifications : Measuring Range Accuracy Resolution Humidity 0~100% RH 0~20%RH;±4.0%20~40%RH;±3.0%40~60%RH;±2.0%60~80%RH;±3.0%80~100%RH;±4.0% 0.1 Temperature -35~100℃-31~212℉ -35~-10℃/-31~14℉;1.0℃/1.8℉-10~-70℃/14~158℉;0.5℃/0.9℉-70~-100℃/158~212℉;1.0℃/1.8℉ Dew Point Temp. -35~100℃-31~212℉ -20~60℃/-4~140℉;1.0℃/1.8℉ Other Read more…


The anemometer measures air velocity, air flow and temperature. It designed for quality control, illness prevention and cure in various environments like constructional-engineering, factory, school, supermarket and household, etc. Features : Air Velocity, ai flow and air temperature measuring Wide Read more…


Features : Dual display Air Velocity level indication Backlight display Area Setting units : CM², M², ft² Air velocity units : m/s, Km/h, ft/min, Knos, Mph Temperature units : ℃, ℉ Battery indication Timing power-off Specifications : Circuit : Based Read more…


Features : Applied standard : IEC61672-1 CLASS2 Frequency weighting : A and C Time weighting : FAST and SLOW MAX/MIN record Data Hold Over Range indication Analog bar-graph indication Specifications : Applied Standard : IEC61672-1 CLASS2 Measuring Level Range : Read more…


Features : Analog bar-graph indication MAX/MIN record Data Hold Lux/Fc selection Auto measurement Timming power-off Backlight Specifications : Measuring range : 0~400k Lux, 0~40k Fc Accuracy : ±3% rgd±10 dgts. (<10,000Lux)±4% rgd±10 dgts. (<10,000Lux) Sampling rate : 2 times/second Operating Read more…


Features : ℃/℉ selection MAX/MIN record Data hold Dew point measuring Backlight display Auto power Off or Non Auto Power Off setting Calibration function Measuring range Accuracy Resolution Humidity 0~1000% RH 0~20%RH; ±4.0%20~40%RH; ±3.0%40~60%RH; ±2.5%60~80%RH; ±3.0%80~100%RH; ±4.0% 0.1 Temperature -20~70℃-4~158℉ Read more…


Features : Sensor : Stabilized electrochemical Gas-specific Measurement range : 0~1000 PPM High Accuracy Large LCD display Accuracy is not affected by humidity Small sensor drift Stable readings MAX reading and Data Hold Low battery consumption, long battery life Specifications Read more…


The anemometer is designed for air velocity and temperature measuring project, quality control, illness prevention and cure and all kinds of environmental air velocity and temperature measurements. It is widely used for the air velocity and temperature measurement at constructional Read more…


Feature : Calibration function User selectable units ℃/℉ MAX/MIN/ Data Hold Large backlight LCD display Specifications : Humidity Measuring Range Level Range Accuracy Resolution Humidity 0%~100% RH 0~20%RH20~40%RH40~60%RH60~80%RH80~100%RH ±4.0%±3.0%±2.5%±3.0%±4.0% 0.1 Temperature -30~70℃-22~158℉ -30~-10℃-22~14℉-10~70℃14~158℉ ±1.0℃±1.8℉±0.5℃±0.9℉ 0.1℃/℉ Operating Conditions -30~60℃; <90%RH (Non Read more…