PT. SRIAYU MULTI KREASI

Jln. Hayam Wuruk No. 2-5

Gedung Harco Glodok Lantai 5 Blok A.42 - Jakarta Barat

PT. SRIAYU MULTI KREASI

Elcometer 6910/2 Setaflash Series 3 Open Cup Tester


Detail Elcometer 6910/2 Setaflash Series 3 Open Cup Tester

Setaflash Series 3 Open Cup Tester | Elcometer 6910/2
SKU: K0US6910M011

Product Description

Flash Point is defined as “the lowest temperature of a liquid at which its vapours will form a combustible mixture with air”. It is a convenient and reliable classification of the “flammability” of many substances.

The Elcometer 6910/2 Setaflash Series 3 Open Cup Tester offers the fastest and most accurate Flash Point instrument at a cost effective price.

Certain substances, classified as “flammable” by Closed Cup Flash Point Testing, may be reclassified as “non-flammable” by combustibility testing. This has significant potential cost reduction implications for the packaging, storage and shipping of many materials.

The Elcometer 6910 Setaflash features an open cup for flash/no-flash finite determinations or sustained combustion tests, audible and on-screen prompts and easy calibration. Flash Point tests can be conducted in less than two minutes with a temperature range from ambient to 300°C (572°F).

A manually operated flame sweeping arm is fitted to the cup and gas is supplied from the integral tank via the control valve. The flash or sustained combustion characteristics of the sample are observed visually by passing the test flame over the sample.

Elcometer offers a range of Flash Point testing equipment, including:

    • Open Cup tests – simulate an un-contained condition, for example a spillage.
    • Closed Cup tests – simulate an enclosed environment, for example storage in a tank or sealed container and are usually specified due to improved precision.

Measuring Flash Point

Most industries need to test the Flash Point of raw materials, products or waste to ensure:

Product quality – as a measure of consistency and performance comparison

Compliance testing – to test safety classification for handling, storage, transport and waste

In-service analysis – tests on in-use oils and other substances for contamination / adulteration

General safety – to evaluate hazard potential

Specifications – to check conformance.

Technical Specifications – Elcometer 6910/2 Setaflash Series 3 Open Cup Tester
Sample Size and Temperature Range
2ml (0.067fl oz) for Flash Points, from ambient up to 100°C (212°F)
4ml (0.135fl oz) for Flash Points between 100°C to 300°C (212°F to 572°F)
Test Times
1 to 99 minutes
Default Values
1 minute for Flash Points, from ambient up to 100°C (212°F)
2 minutes for Flash Points between 100°C to 300°C (212°F to 572°F)
Cup Material
Aluminium
Dimensions
256 x 280 x 256mm (10.1 x 11.0 x 10.8″)
Weight
4kg (8.8lb)
Certificate available
Certificate of Calibration: issued for Fixed Calibration equipment and shows readings and traceability.
Packing List

    • Elcometer 6910 Setaflash ‘Series 3’ open cup tester
    • 2ml (0.067fl oz) syringe
    • gas canister and ignitor
    • silicone rubber tubing for gas canister to gas jet connection
    • silicone sample well ‘O’ ring seal for cup/lid red coloured)
    • viton sample well ‘O’ ring seal for cup/lid (black coloured)
    • mains power cable
    • automatic flash detector probe
    • Series 3 manuals (on CD)
    • operating instructions

 

 

Have any Question or Comment?

Tinggalkan Balasan

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

PRODUK KAMI

VISITOR