1. EC Specifications

  • EC Range : 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
  • EC Resolution : 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
  • EC Accuracy (@25ºC/77ºF) : ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
  • EC Calibration : 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm

2. TDS Specifications

  • TDS Range
    0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**
  • TDS Resolution
    0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
  • TDS Accuracy (@25ºC/77ºF)
    ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
  • TDS Calibration
    through EC calibration
  • TDS Conversion Factor
    0.40 to 0.80 (default value is 0.50)
  • Salinity Specifications
  • Salinity Range
    0.0 to 400.0% NaCl, 2.00 to 42.00 PSU, 0.0 to 80.0 g/L*
  • Salinity Resolution
    0.1% NaCl, 0.01 PSU, 0.01 g/L
  • Salinity Accuracy (@25ºC/77ºF)
    ±1% of reading

3. Temperature Specifications

  • Temperature Range
    -20.0 to 120.0 ºC, -4.0 to 248.0 °F
  • Temperature Resolution
    0.1 °C, 0.1 °F
  • Temperature Accuracy : ±0.5 °C, ±0.9 °F
  • °C/°F : Yes

4. Additional Specifications

  • EC/TDS/Salinity Temperature Compensation :
    Automatic -5 to 100º C (23 to 212º F) NoTC – can be selected to measure absolute conductivity.
  • Conductivity Temperature Coefficient : 0.00 to 6.00% / ºC
  • GLP : Yes
  • Logging : up to 1000 (400 for basic mode) records organized in: manual log-on-demand (max. 200 logs), manual log-on-stability* (max. 200 logs), interval logging† (max. 600 samples; 100 lots)
  • Connectivity : 1 micro USB port for charging and PC connectivity, 1 USB port for storage
  • Environment : 0 to 50°C (32 to 122°F), RH max 95% non-condensing
  • Battery Type/Life : Built-in rechargeable battery with up to 8 hours of continuous use
  • Power Supply : 5 VDC adapter (included)
  • Dimensions : 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
  • Weight : 250 g (8.82 oz)