Detail Hanna Meter With ATC And Extended Range – HI5321

The HI5321 is an advanced research grade benchtop EC/TDS/Salinity/Resistivity meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity.

The HI5321 is supplied with the HI76312 four-ring conductivity probe that operates over a wide range from 0.000 μS/cm to 1000.0 mS/cm*. The meter can be set to auto-ranging in which the meter chooses the appropriate conductivity range from seven ranges or fixed range in which the meter will only display reading in μS/cm or mS/cm.  All readings are automatically compensated for temperature variations with a built in temperature sensor. The temperature correction coefficient is adjustable from 0.00 to 10.00 %/ °C.

The HI5321 can be calibrated up to four points with a choice of six pre-programmed conductivity standards or user defined custom standards. Resistivity, TDS, Practical Salinity (PSU) and Natural Seawater Scale are calibrated through conductivity. The  % NaCl is calibrated to single point with the HI7037 salinity standard. The calibration data including date, time, and standards used, offset and cell factor can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.

For the measurement of high purity water used in pharmaceutical manufacturing, the HI5321 is programmed with the first two stages of the USP <645> method.  Once a stage is met a report is generated and can be saved. Up to 200 reports can be stored and transferred to a Windows® compatible computer a USB cable and software (sold separately).

Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points can be recorded in 100 lots with 50,000 records max/lot and exported to a computer for data review and storage.

EC Specifications

  • EC Range
    0.000 to 9.999 μS/cm, 10.00 to 99.99 μS/cm, 100.0 to 999.9 μS/cm, 1.000 to 9.999 mS/cm, 10.00 to 99.99 mS/cm, 100.0 to 1000.0 mS/cm actual EC*
  • EC Resolution
    0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
  • EC Accuracy (@25ºC/77ºF)
    ±1% of reading (±0.01 μS/cm)
  • EC Calibration
    automatic standard recognition (0.000 μS/cm, 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm) or user standard; single point or multi-point calibration

TDS Specifications

  • TDS Range
    0.000 to 9.999 ppm, 10.00 to 99.99 ppm, 100.0 to 999.9 ppm, 1.000 to 9.999 ppt, 10.00 to 99.99 ppt, 100.0 to 400.0 ppt actual TDS* (with 1.00 factor)
  • TDS Resolution
    0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 ppt
  • TDS Accuracy (@25ºC/77ºF)
    ±1% of reading (±0.01 ppm)

Resistivity Specifications

  • Resistivity Range
    1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
  • Resistivity Resolution
    0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
  • Resistivity Accuracy
    ±2% of reading (±1 Ω•cm)

Salinity Specifications

  • Salinity Range
    practical scale: 0.00 to 42.00 psu; natural seawater scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0%
  • Salinity Resolution
    0.01 for practical scale/natural seawater scale; 0.1% for percent scale
  • Salinity Accuracy (@25ºC/77ºF)
    ±1% of reading
  • Salinity Calibration
    percent scale—one-point (with HI7037 standard)

Temperature Specifications

  • Temperature Range
    -20.0 to 120.0 ºC**; -4.0 to 248.0 ºF**; 253.15 to 393.15 K**
  • Temperature Resolution
    0.1 °C, 0.1 °F, 0.1 K
  • Temperature Accuracy
    ±0.2 °C; ±0.4 °F; ±0.2 K (without probe)
  • Temperature Compensation
    disabled, linear and non-linear (natural water)
  • Temperature Coefficient
    0.00 to 10.00 %/°C
  • Reference Temperature
    5.0 to 30.0 °C

Additional Specifications

  • Cell Constant
    0.0500 to 200.00
  • Cell Type : 4 cells
  • Electrode/Probe
    HI76312 platinum, four-ring EC/TDS probe with and 1 m (3.3’) cable (included)
  • Profiles : up to 10, 5 each channel
  • USP ⟨645⟩ Compliant : yes
  • GLP
    cell constant, reference temperature, temperature coefficient, calibration points, calibration time stamp, and probe offset for conductivity
  • Logging
    record: 100,000 data point storage, up to 100 lots with max. 50,000 records/lot; interval: settable between 1 second and max log time of 180 minutes; type: automatic, manual, AutoHOLD; additional: 200 records USP
  • Display
    color graphic LCD with on-screen help, graphing, and custom color configuration
  • Connectivity : USB
  • Environment
    0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing
  • Power Supply
    12 VDC adapter (included)
  • Dimensions
    160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)
  • Weight
    1.2 kg (2.64 lbs.)