PT. SRIAYU MULTI KREASI

Jln. Hayam Wuruk No. 2-5

Gedung Harco Glodok Lantai 5 Blok A.42 - Jakarta Barat

PT. SRIAYU MULTI KREASI

Hanna HI96702 Copper High Range Portable Photometer


Detail Hanna Copper High Range Portable Photometer – HI96702

The HI96702 portable photometer is for the measurement of copper in a wide variety of water samples. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Check – Allows for performance verification and calibration of the meter using NIST traceable standards.

GLP – Review of the last calibration date

Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.

Battery status indicator – Indicates the amount of battery life left.

Built in timer – Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.

Error messages – Messages on display alerting to problems including no cap, high zero, and standard to low.

Cooling Lamp Indicator – To maintain the desirable wavelength to be used for absorbance it is necessary to ensure component are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken.

Units of measure – Appropriate unit of measure is displayed along with reading.

Significance of Use – Due to its malleability, thermal and electrical conductivity, and corrosion resistance, copper is used in a variety of industrial and technological applications. Copper may also be present in natural water and effluents due to widespread use to control biological growths in reservoirs and distribution pipes.

Absorbance Specifications

Light Source :tungsten lamp

Light Detector : silicon photocell with narrow band interference filter @ 575 nm

Additional Specifications

Range
0.00 to 5.00 mg/L (ppm)

Resolution
0.01 mg/L (ppm)

Accuracy @ 25°C (77°F)
±0.02 mg/L ±4% of reading

Method
adaptation of the USEPA approved bicinchoninate method

Auto-off
after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder

Environment
0 to 50°C (32 to 122°F); RH max 95% non-condensing

Weight
360g (12.7oz.)

Battery Type
9V battery

Dimensions
193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)