Hanna HI96714 Cyanide Portable Photometer


Detail Hanna Cyanide Portable Photometer – HI96714

The HI96714 portable photometer is for the measurement of cyanide. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

Features at-a-glance

CAL Check™ – Allows for performance verification and calibration of the meter using NIST traceable standards.

GLP – Review of the last calibration date.

Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on.

Battery status indicator – Indicates the amount of battery life left.

Built-in timer – Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.

Error messages – Messages on display alerting to problems including no cap, high zero, and standard too low

Cooling lamp indicator – To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken.

Units of measure – Appropriate unit of measure is displayed along with reading.

Absorbance Specifications

Light Source
tungsten lamp
Light Detector
silicon photocell with narrow band interference filter @ 610 nm

Additional Specifications

  • Range
    0.000 to 0.200 mg/L (ppm)
  • Resolution
    0.001 mg/L (ppm)
  • Accuracy @ 25°C (77°F)
    ±0.005 mg/L ±3% of reading
  • Method
    adaptation of the Standard Methods for the Examination of Water and
  • Wastewater, 18th edition, Pyridine-Pyrazolone method
  • Auto-off
    after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
  • Environment
    0 to 50°C (32 to 122°F); RH max 95% non-condensing
  • Weight
    360g (12.7oz.)
  • Battery Type
    9V battery
  • Dimensions
    193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)