Detail Hanna Waterproof Portable Meter – HI98197

EC Range
0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)

EC Resolution
0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm

EC Accuracy
±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)

EC Calibration
automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)

TDS Range
0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)

TDS Resolution
0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)

TDS Accuracy
±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)

TDS Calibration
based on conductivity calibration

Resistivity Range
1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm

Resistivity Resolution
0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm

Resistivity Accuracy
±1% of reading (±10 Ω or 1 digit, whichever is greater)

Resistivity Calibration
based on conductivity calibration

Salinity Range
% NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale – UNESCO 1966: 0.00 to 80.00 (ppt)

Salinity Resolution
0.1%; 0.01

Salinity Accuracy
±1% of reading

Salinity Calibration
max. one point only in % range (with HI7037 standard); use conductivity calibration for all other ranges

Temperature Range
-20.0 to 120.0°C (-4.0 to 248.0°F)

Temperature Resolution
0.1°C (0.1°F)

Temperature Accuracy
±0.2°C; ±0.4°F (excluding probe error)

Temperature Calibration
one or two points

Temperature Compensation
noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)

Measurement Modes
autorange, autoend, lock and fixed range

Reference Temperature
15°C, 20°C and 25°C

Temperature Coefficient
0.00 to 10.00 %/°C

TDS Factor
0.40 to 1.00

Electrode/Probe
HI763123 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m cable (included)

Log-on-demand
400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)

Memorized Profiles
up to 10

PC Connectivity
opto-isolated USB with optional HI 92000 software and micro USB cable

Battery Type/Life
1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight

Auto-off
user selectable: 5, 10, 30, 60 min or can be disabled

Environment
0 to 50°C (32 to 122°F); RH 100% (IP67)

Dimensions
185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)

Weight
400 g (14.2 oz.)