Detail Hioki Safety Hitester 3258
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
- Measurement parameter
AC voltage (AC potential bridge) - Objects of measurement
Insulated conductors (IV or CV equivalent, min. 100 mm² x-section), metal conductors Note: Not usable on shielded conductors - Measurement range
420.0V/ 600V AC (Auto) - Measurement values
True RMS - Max. rated voltage to earth
600V AC rms - Influence of adjacent wiring
±5% rdg. or less - Temperature characteristics
0.05 % rdg./ °C - Display
Digital LCD, max. 4200 digit (zero suppress at 10 digits or less) - Display refresh rate
Approx. once every 0.6 seconds - Display response
2.4 s or less - Functions
Data hold function, auto-power off, low battery warning - Power supply
LR6 (AA) alkaline battery ×6, Continuous use: 14 hr (Power ON, no measurement), or 1-minute measurements for 1000 times, or 5-minute measurements for 200 times - Dimensions and mass
51mm (2.01in) W × 275mm (10.83in) H × 37.5mm (1.48in) D (one probe), 670g (23.6oz)