Detail Hioki Clamp On Ac/dc Hitester 3284
The 3284 is an AC/DC current and voltage clamp meter with analog output capabilities and a peak hold function.
- Analog output for current measuring level, current measuring waveform, or frequency measuring level
- Peak hold function displays the crest value of the inrush curent occurring when electrical equipment starts
- AC+DC mode enables measurement of the RMS value of full or half wave rectified waveforms
Specifications :
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
- DC current : 20.00/ 200.0 A, Basic accuracy: ±1.3 % rdg. ±3 dgt.
- AC current : 20.00/ 200.0 A (10 Hz to 2 kHz, True RMS),
Basic accuracy 45-66 Hz: ±1.3 % rdg. ±3 dgt. - DC voltage : 30.00 V to 600 V, 3 ranges, Basic accuracy: ±1.0 % rdg. ±3 dgt.
- AC voltage : 30.00 V to 600 V, 3 ranges (10 to 1 kHz, True RMS),
Basic accuracy 45-66 Hz: ±1.0 % rdg. ±3 dgt. - Crest factor : 2.5 or less (1.5 at 200 A, 1.7 at 600 V)
- Monitor, Analog output : DC, or AC 1 V/ f.s., Level output, Waveform output: DC to 20 kHz bandwidth (±3dB)
- Resistance, Continuity check : N/A
- Frequency : 1.00 Hz to 1000 Hz, Basic accuracy: ±0.3 % rdg. ±1 dgt.
- Other functions : AC+DC mode, Maximum/ Minimum/ Average value record function, Data hold, Peak hold, Auto power off, Auto zero
- Display : Display refresh rate: 4 times/s (FAST), 1 time/3s (SLOW), 4 times/s (bar graph)
- Power supply : 6F22 (Stacked manganese battery) ×1, Continuous use: 25 hours, or AC adapter 9445-02/-03
- Core jaw dia. : φ 33 mm (1.30 in)
- Dimensions and mass : 62 mm (2.44 in) W × 230 mm (9.06 in) H × 39 mm (1.54 in) D, 460 g (16.2 oz)