Detail LUTRON GCH-2018 CO2 METER :

  • NDIR method principal for CO2 (Carbon dioxide) measurement, available for long term operation
  • High repeatability and high accuracy
  • Two probes, one is for CO2/Temp. measurement, the other probe is for humidity/Temp./Dew point measurement
  • Separate probe, easy operation and convenient for remote measurement
  • CO2 function with alarm setting
  • Can set the altitude (height) value with default for compensation
  • Humidty measurement with fast response time
  • Large S-TN LCD, high contrast, easy readout
  • Data hold function to freezing the desired value on display
  • Records maximum and minimum readings with recall
  • RS232/USB computer interface
  • Microprocessor circuit assures maximum possible accuracy, provides special functions and features
  • Heavy duty and compact housing with hard carying case, designed for easy carry out and operation
  • Auto shut off is available to save battery life
  • Power suppy from batteries or DC 9V adapter in

SPECIFICATIONS :

  1. Circuit : Custom one-chip of microprocessor LSI circuit
  2. Display :
    LCD size : 52×38 mm
    dual function LCD display
  3. Measurement : CO2 (carbo dioxide), temp. Humidity, dew point, Temp.
  4. Unit :
    CO2 : ppm
    Humidity : % RH
    Dew point : ℃ ℉
    Temp : ℃ ℉
  5. Response time : CO2
    < 2 Min. typically
    Reach the 63% reading value
    * Depend the environment air circulation
  6. CO2 Altitude (Height) value setting : 0 to 9.000 meters (For precision measurement, it need to set the mete’s environment altitude (height) value for the compensation)
  7. Temp. compensation : Automatic temp. compensation
  8. Advanced setting :
    Auto power off enable/disable setting
    ℃ ℉ setting
    CO2 alarm value setting
    CO2 altitude value setting
  9. Alarm setting : For CO2 measurement only
  10. Data hold : Freeze the display reading
  11. Memory recall : maximum and minimum value
  12. Display sampling time : Approx. 1 second
  13. Power off : Auto shut off saves battery life. Or manual off by push button
  14. Data output : RS 232/USB PC serial interface
    *Connect the optional RS232 cable
    UPCB-02 will get the RS232 plug
    * Connect the optional USB cable
    USB-01 will get the USB plug
  15. Probes no. Two probes :
    * Probe 1 is for CO2 temp. measurement
    * Probe 2 is for humidity, Dew point. Temp Measurement
  16. Operating temp : 0 to 50 C
  17. Operating humidity :
    Main instrument : Less than 85 % R.H
    CO2 probe : Less than 85% RH
    Humidity measurement : 0 to 95% RH
  18. Power supply : 1.5 V battery (UM-3, AA) x 6 PCs,  or equivalent
  19. Power current :
    CO2 measurement :
    *
    Approx. DC 9.6 mA for 90% period
    * Approx. DC 128 mA 10% period
    Humidity measurement  : Approx. DC 5.6 mA
  20. Weight :
    Main instrument : 372g/0.82 LB (Including battery)
    CO2 probe : 158g/0..35 LB
    Humidity probe : 82g/0.18 LB
  21. Dimension :
    Main instrument : 173x68x42 mm
    CO2 probe : 185x38x26 mm
    Humidity probe : 200x23x19 mm