Detail LUTRON GCH-2018 CO2 METER :
- NDIR method principal for CO2 (Carbon dioxide) measurement, available for long term operation
- High repeatability and high accuracy
- Two probes, one is for CO2/Temp. measurement, the other probe is for humidity/Temp./Dew point measurement
- Separate probe, easy operation and convenient for remote measurement
- CO2 function with alarm setting
- Can set the altitude (height) value with default for compensation
- Humidty measurement with fast response time
- Large S-TN LCD, high contrast, easy readout
- Data hold function to freezing the desired value on display
- Records maximum and minimum readings with recall
- RS232/USB computer interface
- Microprocessor circuit assures maximum possible accuracy, provides special functions and features
- Heavy duty and compact housing with hard carying case, designed for easy carry out and operation
- Auto shut off is available to save battery life
- Power suppy from batteries or DC 9V adapter in
SPECIFICATIONS :
- Circuit : Custom one-chip of microprocessor LSI circuit
- Display :
LCD size : 52×38 mm
dual function LCD display - Measurement : CO2 (carbo dioxide), temp. Humidity, dew point, Temp.
- Unit :
CO2 : ppm
Humidity : % RH
Dew point : ℃ ℉
Temp : ℃ ℉ - Response time : CO2
< 2 Min. typically
* Reach the 63% reading value
* Depend the environment air circulation - CO2 Altitude (Height) value setting : 0 to 9.000 meters (For precision measurement, it need to set the mete’s environment altitude (height) value for the compensation)
- Temp. compensation : Automatic temp. compensation
- Advanced setting :
Auto power off enable/disable setting
℃ ℉ setting
CO2 alarm value setting
CO2 altitude value setting - Alarm setting : For CO2 measurement only
- Data hold : Freeze the display reading
- Memory recall : maximum and minimum value
- Display sampling time : Approx. 1 second
- Power off : Auto shut off saves battery life. Or manual off by push button
- Data output : RS 232/USB PC serial interface
*Connect the optional RS232 cable
UPCB-02 will get the RS232 plug
* Connect the optional USB cable
USB-01 will get the USB plug - Probes no. Two probes :
* Probe 1 is for CO2 temp. measurement
* Probe 2 is for humidity, Dew point. Temp Measurement - Operating temp : 0 to 50 ◦C
- Operating humidity :
Main instrument : Less than 85 % R.H
CO2 probe : Less than 85% RH
Humidity measurement : 0 to 95% RH - Power supply : 1.5 V battery (UM-3, AA) x 6 PCs, or equivalent
- Power current :
CO2 measurement :
*Approx. DC 9.6 mA for 90% period
* Approx. DC 128 mA 10% period
Humidity measurement : Approx. DC 5.6 mA - Weight :
Main instrument : 372g/0.82 LB (Including battery)
CO2 probe : 158g/0..35 LB
Humidity probe : 82g/0.18 LB - Dimension :
Main instrument : 173x68x42 mm
CO2 probe : 185x38x26 mm
Humidity probe : 200x23x19 mm