Detail LUTRON TM-946 Thermometer 4 Channels :
FAETURES :
- Type K/J, Pt 100 oh, measurement with 4 displays
- Show 4 channels display on the LCD at the same time
- Type K : -199.9 to 1370 °C.
- Type J : -199.9 to 1210 °C.
- Pt 100 ohm : -199.9 to 850 °C.
- °C or °F, 0.1 degree/ 1degree
- 4 channels (T1, T2, T3, T4), T1-T2
- Microcomputer circuit provides intelligent function and high accuracy
- Manual and auto data logger, with flexible sampling time selection, can save max. 16,000 reading data
- Recors maximum and minimum readings with recall
- Data hold function to freezing the desired value
- Offset adjustment for the Type K and Type J measurement.
- Offset adjustment for the Pt 100 measurement.
- Measuring unit can select to °C or °F
- DC 1.5V(UM-4 AAA) battery x 6 PCs
- Build in the input socket for DC 9V power adapter
- RS232 PC seial interface
- Few panel buttons, easy operation
- Built-in low batteryindicator
- Heavy duty and compact housing case
GENERAL SPECIFICATIONS :
- Circuit : Custom one-chip of microprocessor LSI circuit
- Display : LCD size 52 x 38 mm (show channels dspay on the display at the same time)
- Display unit : °C or °F
- Resolution : 0.1°C , 0.1 °F
- Channels : (T1, T2, T3, T4), T1-T2
- Sensor type :
Type K thermocouple probe.
Type J thermocouple probe
PT 100 ohm probe (cooperate with an 0.00385 alpha coefficient, meetDIN IEC 751) - Sampling time of data logger :
Auto : 1 second to 59 minutes and 59 seconds
Manual : Push the data logger button once will save data one time (save the sampling time to 0 second) - Data logger number :
* Max. 16,000 point data logger
* Type K, Type J, 4 channels (T1, T2, T3, T4) : Memory use 4 data point space in the memory
* Pt 100 ohm, 2 channels (T1, T2): Memory use 2 data point space in the memory
*
* T1-T2 : Memory use 4 data point space in the memory - Temp. Compensation : Automatic temp. comepensation for the tpe K/J thermometer
- Linear compensation : Linear compensation for the full range
- Offset, Span adjustment : Available for advanced calibration procedure
- Probe input socket :
* Type K & J : 2 pin thermocouple socket
Pt 100 ohm : Ear phone socket - Over indication : show “—-“
- Data hold : freeze the display reading
- Memory call : Min and Max value
- Sampling time : Approx. 1 second
- Power off : Auto shut off saves battery life or manual off by push button
- Data output : RS 232 PC serial interface
- Operating Temp : 0 to 50 °C .
- Operating humidity : Less than 80% RH
- Power supply : DC 1.5 V battery (UM4/AAA) x 6 PCs, or equivalent
- Power current : Approx DC 9 mA
- Weight : 310 g/0.68 LB
- Dimension : 174x68x42 mm