PT. SRIAYU MULTI KREASI

Jln. Hayam Wuruk No. 2-5

Gedung Harco Glodok Lantai 5 Blok A.42 - Jakarta Barat

PT. SRIAYU MULTI KREASI

LUTRON YK-2005AM ANEMOMETER


Detail LUTRON YK-2005AM ANEMOMETER :
  • Air velocity :  m/S, Ft/min, Km/h, Knots, Mile/h,
  • Air flow : CMM ( m^3/min.) and CFM ( ft^3/min. )
  • Air temperature (°C, °F)
  • Type K/J thermocouple thermometer
  • Real time data logger, build in clock (hour-min.-sec-year-month-date)
  • Auto data record, 16.000 Data logger no
  • Wide sampling time adjustment range from two seconds to 8 hours 59 minutes 59 seconds
  • RS232 computer interface
  • Can default auto power off or manual power off
  • Can default the air velocity, air flow, Temp. unit
  • Air flow measurement can set the area dimension
  • Multi-function with with easy operation
  • Low-friction ball vane wheels make sure high accuracy in high and low velocities
  • Metal vane, high reliability]
  • Large LCD with multiple display
  • Data hold, record max. and min. reading
  • Microcomputer circuit provides special function and offer high accuracy
  • Air temp. used thermistr sensor, fast response time
  • Power by UM3 (1.5V) x 4 batteries or DC 9V adapter
  • RS232 PC serial interface
  • Separate probe, easy for operation of different measurement environment
  • Wide applications : Use this anemometer to check air conditioning and heating systems, measure air velocities, wind tempperature .. etc

GENERAL SPECIFICATIONS :

  • Circuit : Custom one-chip microprocessor LSI circuit
  • Display : LCD size : 58x34mm
  • Measurement unit :
    Air velocity :   m/S, Ft/min, Km/h, Knots, Mile/h,
    Air flow : CMM ( m^3/min.) and CFM ( ft^3/min. )
    Air temperature (°C, °F)
    Type K/ Type J thermometer (°C, °F)
  • Sampling time of data logger : 2 sec to 8 hour 59 min. 59 sec. @ Auto datalogger
  • Sensor structure :
    Air velocity and air flow : Conventional twisted van arm and low friction ball bearing design, vane use metal material
    Air temperature : Thermistor
    Type K/ Type J thermometer : Thermocouple
  • Temperature compensation : Automatic temp. compensation for the Type K/J thermometer
  • Data hold : Freeze the display reading
  • Memory recall : Maximum and minimum value
  • Sampling time of display : Approx. 1 second
  • Power off : Auto shut off saves battery life or manual off by push button
  • data output : RS232 PC serial interface
  • Operating temp : 0 to 50 C (32 to 122 F )
  • Operating humidity : Less than 80% R.H
  • Power supply  (Main instrument ):
    DC 1.5 V battery (UM3) x 4 PCs (Heavy duty type)
    DC 9V adapter input @ AC/DC power adapter is optional
  • Power supply (Clock module) : DC 3V silver battery Type CR2032
  • Power current :
    Approx DC 21.5 mA (Main instrument)
    Approx DC 27.5 mA (Main instrument + Anemometer probe)
  • Weight : 515 g / 1.13 LB (Battery included)
  • Dimension :
    Main instrument :  203x76x38 mm
    Anemometer sensor head : Round, 72 mm Dia.

Have any Question or Comment?