PT. SRIAYU MULTI KREASI

Jln. Hayam Wuruk No. 2-5

Gedung Harco Glodok Lantai 5 Blok A.42 - Jakarta Barat

PT. SRIAYU MULTI KREASI

SD 300 pH & SD 320 Con (IP 67 Waterproof) (Environment)


Features SD 300 pH

Min / Max Value Memory highest and lowest measured value is saved.
Auto Hold freeze and display measurement.
Auto Power Off if unused, the meter automatically switches off after a selected period (0 to 120 min, or deactivated)
Additional Display for pH Electrode and Battery Bar graph display
Low Battery Display “BAT” Automatic Temperature Compensation
Automatic Temperature Compensation (ATC) in pH mode (in the range of 0 – 105 °C) when the temperature probe is connected. Temperature can be input manually, when the temperature probe is not attached.
pH Calibration Automatic Buffer Recognition. Permissible electrodes’ data: Asymmetry: ±55mV/Slope:45…62mV/pH The condition of pH Electrode is checked at each calibration. 1, 2 or 3 point calibration with Lovibond® Standard Buffer, DIN 19266 Buffer or any manually entered Buffer values.
Redox Measurement (ORP) 2 options: “mV” Standard Redox or mV measurement „mVH” Conversion to hydrogen systems according to DIN38404 Part 6
rH Measurement The rH value is calculated from a measured Redox value and a manually input pH value

Delivery Content

Order Code: 4724600 SD 300 pH without electrode, with batteries, protective armouring, instruction manual, guarantee sheet

Order Code: 4724610 SD 300 pH (SET 1) instrument, batteries, pH/temp. plastic-electrode type 230, pH-buffer-set (pH 4.00/7.00/10.00), in case, manual, guarantee sheet

Order Code: 4724611 SD 300 pH (SET 2) as SET1, but with pH / temperature plastic-electrode type 225, temperature sensor Pt 1000, manual, guarantee sheet

Assessories

Order code Article
721230BNC pH/temp.-electrodetype 230 plastic/gel/temperature NTC30kOhm (SET 1)
721225BNC pH-electrodeplastic/gel-type 225 (SET 2)
721235BNC pH-electrode glass/gel-type 235
721240BNC Redox-electrode plastic-type 240
72 12 45 PT1000Temperature sensor (SET 2)
41 86 09 KClsolution, 3 molar saturatedwith AgCl, 100 ml
72 12 50 pH buffer-set 4.00/7.00/10.00 (25°C)
72 12 52 pH buffer 4.00 (25°C) 1 litre
72 12 54 pH buffer 7.00 (25°C) 1 litre
72 12 56 pH buffer 10.00 (25°C) 1 litre
19 50 70 Redox calibration solution,470 mV, 100 ml
72 46 20 USB 300 cable,for connection to a computer
72 46 25 GSOFT 3050 data transmissionsoftware with logger for setting,

reading and printing of stored data

72 50 60 Case with foam inlet

Have any Question or Comment?

Tinggalkan Balasan

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *

PRODUK KAMI

VISITOR