PT. SRIAYU MULTI KREASI

Jln. Hayam Wuruk No. 2-5

Gedung Harco Glodok Lantai 5 Blok A.42 - Jakarta Barat

PT. SRIAYU MULTI KREASI

Vickers Hardness Testing Machines HV-110


HV-110 SERIES 810-Vickers Hardness Testing Machines

Description :

The manual line up of the HV-100 series has the following benefits :

  • 144 mm (5.1 inch) colored touchscreen display (Type A) with higher visilibity, easy to operate user interface
  • Digimatic output for report creation
  • USB stick data export
  • Electronic test force change
  • Max. specimen height up to 210mm
  • LED illumination for best image
  • High number of accessories
  • Vickers, Knoop, Brinnell and KC fracture toughness measurement
  • Supprots Brinelltest up to 62.5 KG with an optional test force weight.

Features :

  • Test force : N: 9,807; 19,61; 29,42; 49,03; 98,07; 196,1; 294,2; 490,3 (kgf): 1; 2; 3; 5; 10; 20; 30; 50
  • External dimensions :
    System A : 307(W) x 696 (D) x 786 (H) mm
    System B /C/D :  307(W) x 672(D) x 875 (H) mm
  • Objective lens : Up to 3 pcs. mountable (one standard lems 10x mounted as standard)
  • Force dwell time : 5-999 sec (selectable)
  • Optical system : Infinity corrected optical system
  • Illumination unit : LED light
  • Standard : JIS B 7725, ISO 6507-2
  • Data output : RS-232C, Digimatic, USB 2.0 interface
  • Indenter approach speed : 60µm/s, 150µm/s selectable
  • Control panel : Built in touch panel, 5.7 inch color LCD (HM-110A/120A for system A), Control Software (PC for system B/C/D)
  • Functions : Calculation of Vickers/ koop*2/ Brinnel*3 hardness, and ceramic fracture toughness based on IF method (JIS R1697), 3 display format (standard, list, simple), GO/NG judgement, test condition guide, curve and user correction, hardness corresponding value, statistic calculation
  • Main unit mass : HV-110 : Approx 60kg
  • Otput : Digimatic, Serial, USB2.0 series A (for memory)*1, USB2.0 B type (for system communication)
  • Resolution of diagonal length of an indentation : Objective lens less than 50X: 0.1µm (objective lens more than 50x:0.01 µm)
  • Specimen dimensions  : System A: height 210mm, depth 170mm (when using flat anvil)System B: height 181mm, depth 170mm (when using manual XY stage 50X50mm)System C: height 172mm, depth 170mm, System D: height 132mm, depth 170mm
  • Test force control : Motor driven and manual operation

Have any Question or Comment?